
The 1z0-996-22 PDF Dumps Greatest for the Oracle Exam Study Guide!
Read Online 1z0-996-22 Test Practice Test Questions Exam Dumps
Oracle 1z0-996-22 certification exam is designed to test the skills and knowledge of professionals who are involved in the implementation of Oracle Utilities Customer Cloud Service 2022. Oracle Utilities Customer Cloud Service 2022 Implementation Professional certification exam is ideal for individuals who are looking to improve their skills in customer service, billing, and meter data management using Oracle Utilities Customer Cloud Service.
NEW QUESTION # 21
There has been a meter exchange at a service point in the past year.
How many installation events exist for the service point for the past year?
- A. Two
- B. None
- C. Four
- D. One
- E. Three
Answer: D
NEW QUESTION # 22
When a customer has a specific price for a defined quantity which is different to other customers, where is this specific price for the related Bill Factor defined?
- A. Bill Factor Characteristic
- B. Account Characteristic
- C. Bill Factor Value
- D. Service Agreement - Contract Value
- E. Calculation Rule
Answer: D
NEW QUESTION # 23
Which configuration steps are required to derive loss-adjusted kWh on a measuring component based on a loss factor value related to a service point?
- A. Configure a factor and derivation algorithm, and then associate the factor to the Measuring Component Type and the derivation algorithm to the service point.
- B. Configure an SQI and the derivation algorithm, and then associate the algorithm to the Measuring Component Type and SQI to the service point.
- C. Configure a factor and derivation algorithm, and then associate both to the Measuring Component Type and service point.
- D. Configure a Service Point Characteristic Type, factor, derivation algorithm, and Service Quantity Identifier (SQI), and then associate the SQI and derivation algorithm to the Measuring Component Type and the characteristic value to the service point.
- E. Configure a Service Point Characteristic Type and derivation algorithm, and then associate the algorithm to the Measuring Component Type and the characteristic value to the service point.
Answer: B
NEW QUESTION # 24
Your client has the following requirements:
Many customers are installing their own solar electrical generation equipment. When these customers generate more electricity than required for their own use, the surplus can he exported back to the power grid.
In order to measure this generation, we have installed special scalar devices. These devices have separate registers to measure the energy generated (export) and the energy received (import) from the National Grid. Both reads will be stored in kWh, but the import is subtractive and export is consumptive.
What solution should you choose to configure the measuring component types for these specific requirements?
- A. Create two service points: one for subtractive import and the other for consumptive export.
- B. Create one new measuring component type for creating a new measuring component that will be linked to two different scalar devices (one for import and the other for export).
- C. Create one new measuring component type for creating two measuring components (one for import and the other for export) that will be linked to one scalar device.
- D. Create two new measuring component types (one for subtractive import and the other for consumptive export) to enable the creation of two measuring components that will be linked to one scalar device.
Answer: D
NEW QUESTION # 25
Your implementation requires an installation of two types of devices:
Electric Smart Meter
Gas Manual Meter
Which two Device Type attributes are required to identify these device types? (Choose two.)
- A. Device Business Object
- B. Service Type
- C. Manufacturer
- D. Valid Measuring Component Types
- E. Serial Number
Answer: B,D
NEW QUESTION # 26
Your client has three requirements:
1. Apply validations on meter reads coming from the Data Collectors.
2. If a meter read does not pass the validation, an error will be generated and assigned to a user.
3. Retry the validation every 30minutes for the errors in case the issue is related to configuration.
Which statement describes the base functions you should use?
- A. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be manually loaded.
- B. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-IMD-RETRY (Retry Initial Measurement Data Processing)
- C. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be loaded after 30 minutes.
- D. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, andthen processedby the algorithm D1-COMP-TD (Complete To Do Entries).
- E. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-CRE-IMDTD (Create To Do)
Answer: B
Explanation:
The base functions that you should use to meet your client's requirements are the following:
Apply validations on meter reads coming from the Data Collectors: You can use the Oracle Utilities Meter Data Management (MDM) Cloud Service to perform validation, editing, and estimation (VEE) on the initial measurement data (IMD) that is loaded from the Head End system or other source. MDM has a set of predefined VEE rules that can be configured and customized to check the accuracy and completeness of the meter reads. You can also define your own VEE rules using the VEE Rule Maintenance feature. MDM applies the VEE rules to the IMD based on the VEE Group and the VEE Execution Type that are associated with the device configuration and the service point. MDM also supports manual VEE for users to review and edit the IMD.
If a meter read does not pass the validation, an error will be generated and assigned to a user: You can use the To Do feature to create and assign tasks for users to resolve the VEE exceptions that are generated when the IMD fails the validation. You can configure the system to automatically create a To Do entry for each VEE exception or for a group of VEE exceptions based on the To Do Creation Algorithm on the VEE Rule. You can also specify the To Do Type, the To Do Status, the To Do Priority, and the To Do Assignee for the To Do entry. The To Do entry will contain the details of the VEE exception, such as the IMD ID, the VEE Rule ID, the VEE Group ID, and the VEE Execution Type ID. The user can access the To Do entry from the To Do List or the 360 Degree View device portal and take the appropriate action to correct the IMD or the VEE rule.
Retry the validation every 30 minutes for the errors in case the issue is related to configuration: You can use the IMD Retry feature to automatically reprocess the IMD that has VEE exceptions after a specified interval. You can configure the system to set the Next Retry Date/Time on the IMD to 30 minutes after the VEE exception is generated. You can also specify the Maximum Number of Retries and the Retry Interval Algorithm on the VEE Rule. The system will run the algorithm D1-IMD-RETRY (Retry Initial Measurement Data Processing) periodically to identify the IMD that has a Next Retry Date/Time that is less than or equal to the current date and time. The algorithm will then reapply the VEE rules to the IMD and update the VEE results. If the IMD passes the validation, the VEE exception and the To Do entry will be cleared. If the IMD still fails the validation, the Next Retry Date/Time will be updated and the To Do entry will remain open until the user resolves the issue or the maximum number of retries is reached. References: Oracle Utilities Meter Data Management Overview, VEE Rule Maintenance, [To Do], [IMD Retry]
NEW QUESTION # 27
Throughout its lifecycle, an asset's disposition changes as it is moved between locations and service statuses.
Which are valid asset dispositions?
- A. Receiving; In Field; Storage; Retired
- B. Receiving; Installed; Storage; Retired
- C. In Receipt; Installed; In Stores; Retired
- D. In Receipt; In Field; In Stores; Retired
Answer: D
NEW QUESTION # 28
Which entity defines the type of collection process to start based on ageof debt, amount of debt, and type of customer?
- A. Collection Class
- B. Debt Class
- C. Collection Class Control
- D. Collection Process Template
- E. Customer Class
Answer: C
Explanation:
Collection Class Control is the entity that defines the type of collection process to start based on the age of debt, amount of debt, and type of customer. Collection Class Control is a set of rules that determines which collection class (i.e., the collection process template) to assign to a service agreement based on its debt characteristics and customer class1. Collection Class Control also defines the frequency and timing of the collection process assignment and the criteria for canceling a collection process1. Collection Class Control is associated with a debt class, which is a category of debt that defines how it is calculated, aged, and collected2.
Collection Class Control allows you to create different collection strategies for different types of debt and customers. References: Collection Class Control, Debt Class, Oracle Utilities Customer Cloud Service - Get Started
NEW QUESTION # 29
What contains the details of how a bill was calculated and how it will be printed on a bill?
- A. Rate Schedule
- B. Bill Segments
- C. Service Agreement
- D. Calculation Rules
- E. Bill
Answer: B
NEW QUESTION # 30
Which three statements are correct for Adjustment Types? (Choose three.)
- A. They control how adjustments appear on bills.
- B. They can default an Adjustment Amount to adjustments.
- C. They control whether a rate is to be called to calculate an adjustment amount.
- D. They control the valid Service Agreement Types that adjustments can be linked to.
- E. They control the valid Adjustment Profiles that adjustment types can belong to.
Answer: A,C,D
NEW QUESTION # 31
Which statement supports usage transaction calculation?
- A. Bill determinants are derived from the initial measurement data of the measuring components installed at the usage subscription's devices during the calculation period.
- B. Bill determinants are derived from the final measurements for only interval measuring components or devices installed at the usage subscription's service points during the calculation period.
- C. Bill determinants are derived from the initial measurement data of the measuring components devices installed at the usage subscription's service points during calculation period.
- D. Bill determinants are derived from the final measurements of the measuring components or devices installed at the usage subscription's service points during the calculation period.
Answer: D
NEW QUESTION # 32
Within the application, operational devices can be assets or components.
Which two statements are true about components? (Choose two.)
- A. Components are not a class of assets.
- B. Components are attached to assets.
- C. Components can't have specifications.
- D. Components can be installed at locations.
- E. Components have a disposition that tracks their location and status.
Answer: B,D
Explanation:
In Oracle Utilities Customer Cloud Service, components have specific characteristics in relation to assets. The two true statements about components are:
Components are attached to assets (Option A): Components are devices or objects that are physically attached to another device, typically an asset. Examples include communication relays and components that can be attached to analog meters to connect them to smart grids. Components are always associated with another device and cannot exist independently in terms of installation or location.
Components can be installed at locations (Option C): While components are attached to assets, they can be installed at specific locations. The installation of a component is essentially the installation of the asset to which the component is attached. Therefore, components indirectly have a location where they are installed through their associated assets.
References:
Oracle documentation on About Assets and Components: About Assets.
Oracle documentation on Oracle Utilities Customer Cloud Service New Features: Oracle Utilities Customer Cloud 21C What's New.
NEW QUESTION # 33
Which two are "Are SP and Device Ready?" state algorithms for Enable Service? (Choose two.)
- A. Check for Measurement
- B. Customer Device Compatibility Check
- C. Create Service Point
- D. Start Service Agreement
- E. Create Usage Subscription
Answer: A,B
NEW QUESTION # 34
How many bill segment-related financial transactions do pay plans have?
- A. one
- B. depends on the number of bills that will contain the customer's pay plan commitments
- C. none
- D. depends on the number of payments that is part of the pay plan
- E. unlimited
Answer: B
NEW QUESTION # 35
Your customer's initial measurement data (IMD) has been imported and can be viewed through the Measuring Component portal, but is not in the "Final" measurement status.
What can you assume that the IMD has passed?
- A. Multiplier Check Validation
- B. High/Low Check Validation
- C. Sum Check Validation
- D. Critical Validation, High/Low Check Validation, and Sum Check Validation
- E. Critical Validation
Answer: A
NEW QUESTION # 36
Critical validation rules verify the integrity of the initial measurementdata (IMD). If an implementation needs to add new critical validations, where would you configure them?
- A. in the validation algorithm on the IMD Seeder BO (D1-IMDSeeder)
- B. in the schema of the IMD Seeder BO (D1-IMDSeeder)
- C. as new lifecycle algorithms on the IMD Seeder BO (D1-IMDSeeder)
- D. in the pre-processing algorithm of the IMD Seeder BO (Dl-IMDSeeder)
- E. as optionson the IMD Seeder BO (D1-IMDSeeder)
Answer: A
Explanation:
The IMD Seeder BO (D1-IMDSeeder) is used to create and update initial measurement data (IMD) records. It has a system event called "Validation" that specifies the algorithm to perform critical validations on the IMD records. If an implementation needs to add new critical validations, they can either modify the existing algorithm or create a new algorithm and assign it to the "Validation" system event. This way, the new validations will be executed whenever the IMD Seeder BO is invoked. References: Oracle Utilities Customer Cloud Service User Guide, Calculation Rule Validation, Cloud Services Implementation Guide
NEW QUESTION # 37
Which three statements are true about usage subscriptions? (Choose three.)
- A. A usage subscription can have either parent or child service points.
- B. A usage subscription can be configured to include only a portion of a service point usage.
- C. A usage subscription can have many service points.
- D. A usage subscription can have only one service point.
- E. Usage subscriptions are always related to an account.
Answer: A,C,E
NEW QUESTION # 38
The base package usage transaction business object is represented by D2-UsageTransaction. The usage calculation engine or process drives the specifics of the usage to be calculated on this business object.
Based on this, which three configuration areas will have an impact on the usage calculation process? (Choose three.)
- A. Factor Override
- B. TOU map
- C. VEE rule
- D. Usage Rule
Answer: A,B,D
NEW QUESTION # 39
Your client has three requirements:
1. Apply validations on meter reads coming from the Data Collectors.
2. If a meter read does not pass the validation, an error will be generated and assigned to a user.
3. Retry the validation every 30 minutes for the errors in case the issue is related to configuration.
Which statement describes the base functions you should use?
- A. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-IMD-RETRY (Retry Initial Measurement Data Processing)
- B. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-COMP-TD (Complete To Do Entries).
- C. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be manually loaded.
- D. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be loaded after 30 minutes.
- E. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-CRE-IMDTD (Create To Do)
Answer: E
NEW QUESTION # 40
What happens when a device's measuring components are reconfigured (a new measuring component will be read) at a service point?
- A. The original installation event is updated with the "removal" (expire old device configuration) and a new installation event is created to "install" (new device configuration).
- B. The original installation event is updated with the "removal" (expire old device configuration).
- C. A device with a new configuration type is created.
- D. A new installation event is created to "install" (new device configuration).
- E. A device with a new configuration type is created. Moreover, a new installation event is created to 'install" (new device configuration).
Answer: A
NEW QUESTION # 41
Which three statements are true about the different types of measuring components? (Choose three.)
- A. Seconds-per-interval (SPI) is one of the attributes of scalar measuring components.
- B. The measuring component types are physical, standalone, scratchpad, and TOU.
- C. Scalar measuring components contain a single measurement for an arbitrary period of time.
- D. The terms register and channel are synonyms for measuring component.
- E. Only physical measuring components reference a device configuration.
Answer: B,C,D
NEW QUESTION # 42
Your client has installed scalar devices to measure the solar energy generated (Export) and the energy received (Import) from the National Grid. This data is stored in separate measuring components (registers).
The validation rules are generally the same for both measuring components, but there is one exception. The Negative Consumption check applies only toenergy received (import).
Which two are possible configurations resulting in the Negative Consumption rule being checked for energy received (import) only? (Choose two.)
- A. Create two different VEE groups.
- B. Remove the Negative Consumption check from the VEE group.
- C. Use the Skip Flag in the VEE rule.
- D. Modify the base VEE rule.
- E. Use Eligibility Criteria.
Answer: A,E
Explanation:
To apply different validation rules to different measuring components, you can either create two different VEE groups and assign them to the respective measuring components, or use eligibility criteria to specify the conditions under which a VEE rule should be applied or skipped. Both of these options allow you to check the Negative Consumption rule for energy received (import) only, while applying the other validation rules to both measuring components. References:
Oracle Utilities Customer Cloud Service Business User Guide, Chapter 5: Metering, Section 5.3:
Validating Meter Data
Oracle Utilities Customer Cloud Service Administrative User Guide, Chapter 6: Configuring Metering, Section 6.2: Configuring Validation, Estimation, and Editing (VEE)
NEW QUESTION # 43
......
1z0-996-22 Certification All-in-One Exam Guide May-2024: https://realpdf.pass4suresvce.com/1z0-996-22-pass4sure-vce-dumps.html